NEWBTHPL has state-of-the-art test facility for LED Lightings with C-Type Goniophotometer NEWEMI/EMC Test facility approved by FCC/IC.NEW BTHPL empanelled by BEE for Check Testing of Energy Rated productsNEW EESL empanelled BTHPL to test LED Lamps & Street Lights under DELP programNEW BTHPL can now test Batteries, CE Marks & Telecom Products.

Consumer Durable & White Goods

 

Domestic Electric Clothes Washing Machines: BTHPL has become one of the very few test labs in India to have the test facility to conduct various Performance Tests of different Category & Capacity of Domestic Washing Machines as per current Indian Standards (IS 14155:1994) & International Standard(IEC 60456-2010). This established test facility covers Fully Automatic & Semi-automatic as well as Front Loading & Top-loading type. The test facility for Performance Tests covers Determination of Washing Performance; Determination of Wear Suffered by Textile; Rinsing Efficiency; Water Extracting Efficiency; Determination of Water & Energy Consumption Etc. This test facility will also address the requirements of washing machine manufacturers on obtaining the Energy Rating Labels from Bureau of Energy Efficiency(BEE) under Standards & Labeling Program of India.

Household Refrigerating Appliances- Refrigerators (Direct Cool & Frost Free): BTHPL has added another feather to its cap to have the test facility for Domestic Refrigerators in Direct Cool (IS 1476 Pt-1/IEC60335-2 & 60704-2-14) & Frost Free(IS 15750:2006; BS/EN/ISO8561:1996; IEC60335-2 & IEC 60704-2-14) Category where it will be able to join a select group of limited test labs in India to be able to test as per the current National & International Standards including as per the key requirements of Standard & Labeling program of Bureau of Energy Efficiency.

Room Air-Conditioners: Like for the Domestic Refrigerators, BTHPL has also added to its capacity to test Domestic Room Air Conditioners as per the National Standards IS 1391(Part-1) Unitary Air conditioners & IS 1391 (Part-2):1992 (Split Air Conditioners IEC 60335-2-40) for limited test parameters to cover some of the specified tests. Soon it will have the complete test facility to cover all the listed tests to judge the complete performance.

S.No.
Domestic Washing Machine:IS 14155:1994* Test Clause
01
Washing Performance
Cl-11
02
Determination of wear suffered by textile
Cl-12
03
Rinsing Efficiency
Cl-13
04
Water Extraction Efficiency
Cl-14
05
Determination of Water & Energy Consumption
Cl-15
06
Determination of mechanical detergent loss in sump
Cl-16
07
Endurance
Cl-17
08
Finish
Cl-18
09
Safety requirements IS:302-2-7:2012
Cl-8 to 32
S.No.
Refrigerators: IS 1476* Test Clause
01
No-load adjustment
Pt.1(Cl-14.4)
02
No-load performance
Pt.1(Cl-14.5)
03
Thermal insulation
Pt.1(Cl-14.7)
04
High voltage
Pt.1(Cl-14.8)
05
Rated energy consumption
Pt.1(Cl-14.9)
06
Thermostat
Pt.1(Cl-15.1)
07
Insulation resistance
Pt.1(Cl-15.2)
S.No.
Refrigerators: IS 15750:2006* Test Clause
01
Overall dimensions
(Cl-3.3)
02
Energy consumption
(Cl-14)
03
High voltage test
(Cl-19)
04
Insulation resistance
(Cl-20)
05
Marking
(Cl-24)
S.No.
Air-Conditioners: IS:1391(Part 1 & 2)* Related Standard
01
Power factor; Power consumpation test
(pt.1 & 2)
02
Leakage current test; Insulation resistance test
(pt.1 & 2)
03
High voltage test; Earthing resistance test
(pt.1 & 2)
* NABL Inspection Completed & Approval Awaited

 